Flydumps just published the newest APC PB0-200 dumps with all the new updated exam questions and answers.Flydumps provide the latest version of APC PB0-200 and VCE files with up-to-date questions and answers to ensure your exam 100% pass, on our website you will get the free new newest APC PB0-200 version VCE Player along with your VCE dumps.

QUESTION 47
Certkiller .com has a requirement for 24×7 monitoring of the physical environment within its rack
enclosures.
Which solution is the most cost-effective?

A. dedicated power bar/outlet strips in each rack enclosure
B. temperature and humidity sensors in each rack enclosure
C. proprietary software to monitor the internal server temperature
D. carry-out thermography service using a thermal imaging camera

Correct Answer: B
QUESTION 48
The Netshelter VX rack enclosure is compatible with most IT equipment because it compiles with the ____standard, which makes it compatible with 99%of all servers.
A. UL1778
B. EIA310.D
C. EN50091-1
D. NEMA PE-1
Correct Answer: B
QUESTION 49
Which three solutions improve airflow in an enclosure in a raised-floor environment?
A. blanking panels
B. rack air distribution unit
C. enclosure with split rear door
D. enclosure with glass front door
E. temperature and humidity sensors
F. cable management brackets and trays

Correct Answer: ABC
QUESTION 50
An IT server room demands 8kva with an estimated growth of 20%. The company wants an APC UPSs
solution with high availability and serviceability at a low cost.
Which solution would you recommend?

A. a silcon 10 kva
B. a symmetra singl=phase 12 kva LX
C. a symmetra PX with 10 kw of power
D. an infrastructure for small & medium data center solution starting with 10kw

Correct Answer: B
QUESTION 51
Which two service advantages does a Symmetra UPS within Infrastruxure offer over traditional solutions?
A. Mean time repair is reduced
B. Built-in redundancy reduces component failures
C. The service bypass panel allows isolation of UPS
D. The required a Skill level for troubleshooting is reduced.

Correct Answer: AB
QUESTION 52
An enterprise data center manager is in charge of 47 production server several switches hubs routers and workstations. The computer room is backed up by a symmetra PX 40KW with an external battery cabinet giving a runtime of about 22 minutes at full load. They do not have a generator. Forty-two of the 47 servers are critical and the manager wants to shut them down gracefully using his LAN, in order to not damage the operating systems. Which application would you recommend?
A. Enterprise MANAGER
B. PowerChute Business Edition
C. PowerChute Network Shutdown
D. PowerChute Professional Edition

Correct Answer: C
QUESTION 53
An office building has a chiller plant that supplies chilled water throughout the building for general cooling of the occupied spaces. The chilled water is not available outside regular business hours. A tenant is planning to occupy an office in the building,. The new tenant has a computer room for their IT support equipment that occupies 10 racks at an average of 2.7 KW per rack and runs 24 hours a day. Which solution provides the greatest efficiency and reliability for the computer room?
A. roof-top unit
B. chilled-water unit
C. ceiling-mounted unit
D. glycol-cooled unit with economizer
E. refrigerant-based unit with secondary chilled-water cool

Correct Answer: E
QUESTION 54
A site requires UPS power to feed a combination of desktop computer, existing rack mount server loads, and non-rack loads. Assume 35kw of combined load (20kw for servers and 15kw for PCs.) and a three -phase available sourc. What is the highest available, easy-to=manage and easy-to-maintain solution?
A. all Smart-UPS and Back-UPS
B. one 40kw traditional UPS with one PDU for each load type
C. one 20kw three-phase single-module UPS system for each types of load
D. one 40kw N+1 Symmetra PX with overhead and under floor distribution

Correct Answer: D
QUESTION 55
The basement air conditioning unit leaks water onto the data center floor. The facility manager wants to install a water sensor in the data center’s basement and received e-mail notification through the company’s LAN when there is water on the floor. The water sensor uses only normally open or normally closed contacts when water is detected. What should the facility manager do?
A. connect a Network MANAGEMENT card for e-mail notification
B. install powernet manager on an available computer for e-mail notification
C. connect a building management card to the water sensor for e-mail notification
D. connect an environmental monitoring unit to the water sensor for e-mail notification

Correct Answer: D
APC PB0-200 Exam Certification Guide is part of a recommended study program from APC PB0-200 that includes simulation and hands-on training from authorized APC PB0-200 Learning Partners and self-study products from APC PB0-200.Find out more about instructor-led, e-learning, and hands-on instruction offered by authorized APC PB0-200 Learning Partners worldwide